Ultrasound in Medicine & Biology 2006;32(7):1085-1096. DOI:10.1016/j.ultrasmedbio.2006.03.015
Recent studies have attempted to dispel the idea of the longitudinal mode being the only significant mode of ultrasound energy transport through the skull bone. The inclusion of shear waves in propagation models has been largely ignored because of an assumption that shear mode conversions from the skull interfaces to the surrounding media rendered the resulting acoustic field insignificant in amplitude and overly distorted. Experimental investigations with isotropic phantom materials and ex vivo human skulls demonstrated that, in certain cases, a shear mode propagation scenario not only can be less distorted, but at times allowed for a substantial (as much as 36% of the longitudinal pressure amplitude) transmission of energy. The phase speed of 1.0-MHz shear mode propagation through ex vivo human skull specimens has been measured to be nearly half of that of the longitudinal mode (shear sound speed = 1500 ± 140 m/s, longitudinal sound speed = 2820 ± 40 m/s), demonstrating that a closer match in impedance can be achieved between the skull and surrounding soft tissues with shear mode transmission. By comparing propagation model results with measurements of transcranial ultrasound transmission obtained by a radiation force method, the attenuation coefficient for the longitudinal mode of propagation was determined to between 14 Np/m and 70 Np/m for the frequency range studied, while the same for shear waves was found to be between 94 Np/m and 213 Np/m. This study was performed within the frequency range of 0.2 to 0.9 MHz.
pdf download
Copyright © 2006 Elsevier
This article may be downloaded for personal use only. Any other use requires prior permission of the publisher.
Clinic Ultrasound Laboratory (クレメント超音波研究室)
Cleveland Clinic (クリーブランド・クリニック),
Lerner Research Institute
Case Western Reserve University
© 2013
For a comprehensive listing see PUBLICATIONS
Clement GT, Nomura H, Adachi H, Kamakura T, Feasibility of non-contact ultrasound for medical imaging, Physics in Medicine and Biology 2013; 58: 6263-6278
Tang SC, Jolesz FA, Clement GT. A Wireless Batteryless Implantable Ultrasonic Pulser-Receiver. IEEE Trans Ultrason Ferroelectr Freq Control 2011;58:1211-21.
Paltiel HJ, Padua HM, Gargollo PC, Cannon GM Jr, Alomari AI, Yu R, Clement GT. Volumetric ultrasound imaging of tissue perfusion: preliminary results in a rabbit model... Phys Med Biol 2011;56:2183-97.
McDannold N, Clement GT, Black P, Jolesz F, Hynynen K. Focused ultrasound surgery of brain tumors: Initial findings in three patients. Neurosurgery 2010;66:323-32; discussion 332.
Clement GT, Hynynen K. A non-invasive method for focusing ultrasound through the human skull. Phys Med Biol 2002;47(8):1219-36.