Physics in Medicine and Biology 2000;45(4):1071-1083. DOI:10.1088/0031-9155/45/4/319
Non-invasive treatment of brain disorders using ultrasound would require a transducer array that can propagate ultrasound through the skull and still produce sufficient acoustic pressure at a specific location within the brain. Additionally, the array must not cause excessive heating near the skull or in other regions of the brain. A hemisphere-shaped transducer is proposed which disperses the ultrasound over a large region of the skull. The large surface area covered allows maximum ultrasound gain while minimizing undesired heating. To test the feasibility of the transducer two virtual arrays are simulated by superposition of multiple measurements from an 11-element and a 40-element spherically concave test array. Each array is focused through an ex vivo human skull at four separate locations around the skull surface. The resultant ultrasound field is calculated by combining measurements taken with a polyvinylidene difluoride needle hydrophone providing the fields from a 44-element and a 160-element virtual array covering 88% and 33% of a hemisphere respectively. Measurements are repeated after the phase of each array element is adjusted to maximize the constructive interference at the transducer's geometric focus. An investigation of mechanical and electronic beam steering through the skull is also performed with the 160-element virtual array, phasing it such that the focus of the transducer is located 14 mm from the geometric centre. Results indicate the feasibility of focusing and beam steering through the skull using an array spread over a large surface area. Further, it is demonstrated that beam steering through the skull is plausible.
pdf download
Copyright © 2000 IOP
This article may be downloaded for personal use only. Any other use requires prior permission of the publisher.
Clinic Ultrasound Laboratory (クレメント超音波研究室)
Cleveland Clinic (クリーブランド・クリニック),
Lerner Research Institute
Case Western Reserve University
© 2013
For a comprehensive listing see PUBLICATIONS
Clement GT, Nomura H, Adachi H, Kamakura T, Feasibility of non-contact ultrasound for medical imaging, Physics in Medicine and Biology 2013; 58: 6263-6278
Tang SC, Jolesz FA, Clement GT. A Wireless Batteryless Implantable Ultrasonic Pulser-Receiver. IEEE Trans Ultrason Ferroelectr Freq Control 2011;58:1211-21.
Paltiel HJ, Padua HM, Gargollo PC, Cannon GM Jr, Alomari AI, Yu R, Clement GT. Volumetric ultrasound imaging of tissue perfusion: preliminary results in a rabbit model... Phys Med Biol 2011;56:2183-97.
McDannold N, Clement GT, Black P, Jolesz F, Hynynen K. Focused ultrasound surgery of brain tumors: Initial findings in three patients. Neurosurgery 2010;66:323-32; discussion 332.
Clement GT, Hynynen K. A non-invasive method for focusing ultrasound through the human skull. Phys Med Biol 2002;47(8):1219-36.